قابل سفارش
موجود در انبار
Parameter | RPS6U 24 DC |
Factory adjustment | +5.41 VDC ±0.02 V, ±12.5 VDC ±0.05 V (at 60% max. output power) |
Load range | +5.35 VDC nom. (5.35 to 5.45 V accuracy with a load of 3 to 50 A). +12.5 VDC nom. (12.2 to 12.8 V accuracy with a load of 0 to 8 A). -12.5 VDC nom. (-12.2 to -12.8 V accuracy with a load of 0 to 4 A). |
Ripple and noise (20 MHz bandwidth) | <50 mVPEAK-TO-PEAK for all outputs |
Line regulation (±10% change in nominal input) | <±1% for all outputs |
Load regulation (±40% change from 60% max. output power) | <±1% for +5 VDC output. <±2% for ±12 VDC outputs. |
Output overvoltage protection | Yes, with automatic latch off |
Output short-circuit and overload protection | Yes, with automatic recovery |
Output power derating with convection cooling (natural ventilation) | 2%/°C from 50 to 70°C for +5 VDC output. 3%/°C from 60 to 70°C for ±12 VDC outputs. |
Output power derating with forced-air cooling | 2.5%/°C from 60 to 70°C for +5 VDC output. No derating required for ±12 VDC outputs. |
Ordering number | 200-582-200-02h |